Single-point load cells for platforms 600 x 600 mm
![]() |
| APL : Single-point load cells for platforms 600 x 600 mm |
| APL : kg 50, 100, 150, 200, 300, 500 |
| Options on request : |
|
![]() |
| Technical Features : |
| RATED OUTPUT | 2 mV/V +/-10% | |
| TEMPERATURE EFFECT ON ZERO | 0.0017% °C | |
| TEMPERATURE EFFECT ON SPAN | 0.0014% °C | |
| COMPENSATED TEMPERATURE RANGE | - 10°C / + 40°C | |
| OPERATING TEMPERATURE RANGE | - 35°C / + 65°C | |
| CREEP AT NOMINAL LOAD IN 30 MINUTES | 0.015 % | |
| MAX SUPPLY VOLTAGE WITHOUT DAMAGE | 18 Volt | |
| INPUT RESISTANCE | 409 ohm +/- 6 | |
| OUTPUT RESISTANCE | 350 ohm +/- 3 | |
| ZERO BALANCE | +/- 1 % | |
| INSULATION RESISTANCE | >5000 Mohm | |
| SAFE OVERLOAD (% of Full Scale) | 150 % | |
| ULTIMATE OVERLOAD (% of Full Scale) | > 300 % | |
| DEFLECTION AT NOMINAL LOAD | 0.5 mm |
![]() |
![]() |